{"product_id":"uk-force-10-full-face-mask-filters","title":"UK FORCE™ 10 FULL FACE MASK \u0026 FILTERS","description":"\u003ch2\u003eDetails\u003c\/h2\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eA UK made full face, twin cartridge mask with Class 3 heavy duty filter connections. Conforms to BS EN 136:1998.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote: \u003c\/strong\u003eSupplied without filters - see SU2037, SU2038, SU2039 press-to-check filters or SU1237 cartridge filters and SU1238 pre-filters\u003c\/li\u003e\n\u003cli\u003eFully adjustable padded 5-point suspension harness moulds to face shape for excellent seal\u003c\/li\u003e\n\u003cli\u003eExhalation valve to reduce heat and moisture build-up\u003c\/li\u003e\n\u003cli\u003eQuick release buckles\u003c\/li\u003e\n\u003cli\u003ePanoramic lens - impact protection, anti-mist, anti-scratch\u003c\/li\u003e\n\u003cli\u003e\u003ca title=\"Request a size guide\" href=\"https:\/\/www.jspsafety.com\/contentpage\/size-guide-request\" target=\"_blank\" rel=\"noopener\"\u003eRequest a physical size guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePRESS-TO-CHECK™ FILTERS\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eWith the new PressToCheck™ filters you can instantly check that you have the correct seal every time. For use with Force8 and Force10 masks\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFit it..!\u003c\/strong\u003e\u003cbr\u003eDon the mask - Put the straps and harness over your head and pull the straps to a suitably tight and comfortable fit\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePress it..!\u003c\/strong\u003e\u003cbr\u003ePressToCheck™ - Press the front and backs of both filter covers together to stop air from entering through the filters\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCheck it..!\u003c\/strong\u003e\u003cbr\u003eInhale - No air should come through the mask, adjust until it doesn't\u003c\/p\u003e\u003ctable class=\"spec\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth colspan=\"4\"\u003eFilter Marking\u003c\/th\u003e\n\u003cth\u003eMeaning\u003c\/th\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003cth style=\"text-align: center;\"\u003eClass\u003c\/th\u003e\n\u003cth\u003eVapour Filter\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" style=\"text-align: center; background-color: #a44429;\"\u003eA\u003c\/td\u003e\n\u003ctd\u003eOrganic Vapours \u0026amp; Gases with boiling point 65°c \u0026amp; above\u003c\/td\u003e\n\u003ctd rowspan=\"9\" width=\"10\"\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\u003c\/td\u003e\n\u003ctd\u003eLOW Capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" style=\"text-align: center; background-color: #979b9e;\"\u003eB\u003c\/td\u003e\n\u003ctd\u003eInorganic Vapours \u0026amp; Gases (excluding Carbon Dioxide Monoxide)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2\u003c\/td\u003e\n\u003ctd\u003eMEDIUM Capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" style=\"text-align: center; background-color: #fac91c;\"\u003eE\u003c\/td\u003e\n\u003ctd\u003eSulphur Dioxide \u0026amp; other Acidic Vapours \u0026amp; Gases\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3\u003c\/td\u003e\n\u003ctd\u003eHIGH CAPACITY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" style=\"text-align: center; background-color: #94cc30;\"\u003eK\u003c\/td\u003e\n\u003ctd\u003eAmmonia \u0026amp; Ammonia derivatives Vapours \u0026amp; Gases\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"2\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center; background-color: #a44429;\"\u003eA\u003c\/td\u003e\n\u003ctd style=\"text-align: center; background-color: #979b9e;\"\u003eB\u003c\/td\u003e\n\u003ctd style=\"text-align: center; background-color: #fac91c;\"\u003eE\u003c\/td\u003e\n\u003ctd style=\"text-align: center; background-color: #94cc30;\"\u003eK\u003c\/td\u003e\n\u003ctd\u003eCombination Filter, all of the above\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" style=\"text-align: center;\"\u003eP\u003c\/td\u003e\n\u003ctd\u003eParticulate Filter\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eClass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eParticulate Filter\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" style=\"text-align: center;\"\u003eR\u003c\/td\u003e\n\u003ctd\u003eRe-usable particulate filter\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\u003c\/td\u003e\n\u003ctd\u003eLOW Capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" style=\"text-align: center;\"\u003eNR\u003c\/td\u003e\n\u003ctd\u003eSingle shift particulate filter\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2\u003c\/td\u003e\n\u003ctd\u003eMEDIUM Capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" style=\"text-align: center;\"\u003eD\u003c\/td\u003e\n\u003ctd\u003eMeets optional clogging requirements\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3\u003c\/td\u003e\n\u003ctd\u003eHIGH Capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eFILTER EXPIRY\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eThe expiry date printed on the filters is the absolute final date for the life of the filter when unopened and completely sealed from outside contaminants.\u003c\/li\u003e\n\u003cli\u003eOnce the seal has been broken, the filters have a maximum life expectancy of 28 days unless used in high intensity environments.\u003c\/li\u003e\n\u003cli\u003eThe user should carry out their own risk assessment on each use. If there is difficulty in breathing or they can taste\/smell the contaminant through the mask, then the filters must be changed\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"UK FORCE","offers":[{"title":"Medium","offer_id":57419873452419,"sku":"SU2312-1","price":176.04,"currency_code":"GBP","in_stock":true},{"title":"Large","offer_id":57419873485187,"sku":"SU2312-2","price":176.04,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0994\/7031\/1811\/files\/su2036_3_bd7d515d-cfcc-4ad4-b0a3-c2f0a7d8cbd0.jpg?v=1772391886","url":"https:\/\/onlyswim.co.uk\/products\/uk-force-10-full-face-mask-filters","provider":"onlyswim","version":"1.0","type":"link"}